Blood gases and acid–base balance.

Reading guide · Updated 2026-10-20

The analyzer requires JavaScript. Your entries are processed on your device.

Overview

GDS360 concerns adult blood gas interpretation: acid–base balance, compensation, anion gap and oxygenation. The approach relates each result to how it was produced, the sample and the respiratory conditions.

How to use

Open the analyzer to enter a reading and view the available results.

Open analyzer — gds360

Analyze an arterial blood gas in an adult. Enter the available values and their context; calculations, assumptions and limitations follow the entered data.

Individual entry: blood gases and laboratory values are not imported from Patient. Examples are fictional; editing withdraws their evidence and re-entering a value does not restore it.

Method and limitations

Which results belong to the same sampling event?

Before combining values, identify sample type, time, units and temperature convention. A venous or capillary value does not become an arterial value. Results obtained close together must still represent the same clinical state: an intervention between samples may change their relationship.

For oxygenation, the relevant device, settings and measurement conditions are those present when the blood gas was taken. Current respiratory support may not describe that earlier event.

What do pH, PCO₂ and bicarbonate represent?

pH describes the observed acid–base state; PCO₂ and bicarbonate help explain its respiratory and metabolic components. Bicarbonate calculated from pH and PCO₂ depends on those two results and is not a third independent measurement. The local calculation described here uses a 37 °C convention and remains separately identified from the analyser result. [G1–G4]

The quantity must be distinguished from how it was produced. Actual bicarbonate corresponds to the pH–PCO₂ pair and may be calculated by the analyser. Standard bicarbonate refers to standardised conditions. Chemistry total CO₂ is a different analytical result. Their values are not substituted for one another. The same precision applies to the type of base excess and to estimated or co-oximetry-derived saturation. A documented discrepancy is retained and may limit interpretation. [G3, G4]

What does the compensation comparison investigate?

A pH within the usual interval does not exclude an acid–base disorder: different components may have opposing effects. Interpretation therefore considers their consistency. [G1, G2]

When metabolic acidosis is the working hypothesis, Winter compares observed PaCO₂ with that expected for respiratory compensation. A higher or lower PaCO₂ may suggest an additional respiratory component. The comparison depends on the initial hypothesis and the bicarbonate input; its conventional margin does not precisely predict an individual response. It cannot, by itself, date the disorder. [G1, G2]

What do the anion gap and lactate tell us?

The anion gap relates electrolytes and bicarbonate through a specified formula. The convention described for GDS360 uses blood gas electrolytes and local bicarbonate, without potassium. Interpretation requires a reference appropriate to that formula and those measurements. A chemistry anion gap based on chemistry total CO₂ retains a separate identity. [G2]

Lactate is a separate observation interpreted in clinical context. It is not inferred from the anion gap, and its value alone does not establish a cause. Unavailability of either result does not remove the value of other interpretable data.

What does the PaO₂/FiO₂ ratio provide?

The P/F ratio places arterial oxygen pressure in relation to the inspired oxygen fraction used in the calculation. That FiO₂ must be identified and related to the sampling event. A set value, a measurement and an estimate are different kinds of information. Oxygen flow or device name alone does not establish an exact FiO₂. [G5–G9]

During high-flow oxygen or NIV, inspiratory demand, circuit configuration, leaks and measurement site may affect the relationship between set and achieved oxygen fractions. The cited studies explain these mechanisms within their populations and equipment; they do not provide a universal correction. [G6–G9]

P/F describes an oxygenation relationship. ARDS assessment requires additional criteria and respiratory-support conditions; the ratio alone does not establish them. [G5]

When should a conclusion be limited?

Each conclusion depends on its own data. Missing information, suspect quality or incompatible measurements may prevent the affected calculation while independent results remain useful. A value reported as “less than” or “greater than” a bound retains that operator: the bound is not an exact measurement.

References

The sources address acid–base interpretation, the nature of analytical results and oxygenation. Each comment identifies the source’s contribution and the conditions governing its use.

Sources

Full references
Interpretation of Arterial Blood Gases — opens in a new tab

American Thoracic Society — David A. Kaufman. Interpretation of Arterial Blood Gases. Educational resource, EN.

ATS educational resource: acid–base components and compensation reference values. These do not provide an individual prediction of response.

Diagnosis and management of metabolic acidosis: guidelines from a French expert panel — opens in a new tab

Jung B et al. Diagnosis and management of metabolic acidosis: guidelines from a French expert panel. Annals of Intensive Care, 2019. DOI 10.1186/s13613-019-0563-2.

Expert guidance on metabolic acidosis, compensation and anion gap, particularly R1.1–R1.3. Local analytical conventions remain distinct from the recommendations.

CG4+ i-STAT Alinity — opens in a new tab

Abbott Point of Care. CG4+ i-STAT Alinity, IFU art. 765862-01 D, 29 September 2023 ; REF 03P85-25, AN-500, international English. Manufacturer instructions.

CG4+ Alinity instructions, pp.1–4: measured and calculated parameters for the specified configuration. Other cartridges and equivalence with local calculations are not established.

Blood Gas: Clinical Significance — opens in a new tab

Siemens Healthineers Academy. Blood Gas: Clinical Significance.

HCO₃ section: distinction between actual and standard bicarbonate. Manufacturer terminology support; no transfer of coefficients to another analyser.

A New Global Definition of Acute Respiratory Distress Syndrome — opens in a new tab

Matthay MA et al. A New Global Definition of Acute Respiratory Distress Syndrome. American Journal of Respiratory and Critical Care Medicine. 2024;209(1):37–47, first published online in 2023. DOI 10.1164/rccm.202303-0558WS.

Table 1 and notes: ARDS criteria, respiratory support and measurement conditions. P/F alone does not establish the full definition.

Gas composition and pressure in the hypopharynx during high-flow oxygen therapy through a nasal cannula in healthy volunteers with different breathing patterns — opens in a new tab

Yaroshetskiy AI et al. Gas composition and pressure in the hypopharynx during high-flow oxygen therapy through a nasal cannula in healthy volunteers with different breathing patterns. BMC Anesthesiology. 2025;25:416, 23 August 2025. DOI 10.1186/s12871-025-03267-9.

Physiological study in healthy volunteers using one high-flow device. Explains possible differences between set and achieved fractions without a universal patient correction.

FIO₂ in an Adult Model Simulating High-Flow Nasal Cannula Therapy — opens in a new tab

Chikata Y, Onodera M, Oto J, Nishimura M. FIO₂ in an Adult Model Simulating High-Flow Nasal Cannula Therapy. Respiratory Care. 2017;62(2):193–198. DOI 10.4187/respcare.04963.

Adult high-flow model: effects of ventilatory conditions on FiO₂. Bench findings, without individual patient measurement.

Oxygen Supplementation in Noninvasive Home Mechanical Ventilation: The Crucial Roles of CO₂ Exhalation Systems and Leakages — opens in a new tab

Storre JH et al. Oxygen Supplementation in Noninvasive Home Mechanical Ventilation: The Crucial Roles of CO₂ Exhalation Systems and Leakages. Respiratory Care. 2014;59(1):113–120. DOI 10.4187/respcare.02596.

Home NIV study with supplemental oxygen: circuit, leaks and measurement site. Findings do not generalise to every ventilator.

Leaks can dramatically decrease FiO₂ on home ventilators: a bench study — opens in a new tab

Goutorbe P et al. Leaks can dramatically decrease FiO₂ on home ventilators: a bench study. BMC Research Notes. 2013;6:282, 21 July 2013. DOI 10.1186/1756-0500-6-282.

Bench study of one ventilator model: effects of leaks on achieved oxygen fraction. No universal acceptable-leak threshold or individual correction factor.